duke of hamilton wedding

hayward blue essence troubleshooting

The shaft is accessed in the rear of the motor, behind the centrifugal switch. If thats not the problem, try soaking the fingers again, with a stronger solution, and/or leaving them soaking longer. "height": "219",
The pump is 18 yrs. Hi COnnie, great question! However after shutting it manually, the pump wouldnt start again. I am a novice with in ground pools, but is the pool motor supposed to run continuously? However it is not generating enough chlorine and we are adding chlorine more than we should. Seems like filter is dirty , so I bumped it several times (once with motor on to really force water through) that usually does it. Towards the end of last year the pump itself would work but the salt water fixture would not (like it would light up initially but then go to black), I wasnt sure if it was a short or something in either part but ignored it since the season was almost over. Or if pump was off for some time, it can leak water, where it leaks air, when on. Hi Kevin, I think I would check the capacitor(s), maybe replace them if they test weak, or look cracked or damaged. Originally it appears that the arrows are just off a little, but not the case. I also noticed that the repaired motor We live in Arizona, so the automatic freeze setting isnt an issue. Either a leaky valve in front of the pump, loose fitting threaded into pump, or loose pump lid/o-ring, or sometimes a loose drain plug, with no Teflon tape on it, and a missing plug o-ring these can all allow air to draw into the pump. Automatic reset is immediate after error is corrected. It seems to only operate in the highest speed. Or, it could be that the motor is cavitating, and restricting the return side somewhat may balance the flow, if you have a valve or bypass arrangement, or can plug one of the returns, for testing. Impeller turns from inside basket. Hi William, yes an air leak, is what I call it. Good luck! Not sure if I need to purchase a new pump. Is the GFCI test button tripped? Thanks. Click Here to View Replacement Aquarite Parts The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing the , . The motor has all of the same specifications of the Hayward motor that is being replaced, what could possibly cause the motor not ot work? MY PUMP STARTS TO PRIME THEN LOSES IT. My pump was tripping the breaker after about three minutes (consistently when I reset the breaker and turned on the pump, same thing). Initially, look into the pump/strainer housing. Pump lids are often easier to remove when the Filter Air Bleeder is opened, to relieve vacuum pressure. Might be 2-years here is a chart on reading Hayward serial numbers, to find date of manufacture https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, I have to reprime my hayward pump everytime I turn it on. Ive had the pool for 25 years with no problems until now. The pump is pretty hot. If the salt level is below range, add enough salt to achieve a salt level of 3200 ppm. Thank you for the quick response. i have an in ground pool. Pull out the pump basket and reach back thru the volute to feel the impeller with your fingertips (pump off, lol), if you feel any debris, reach in with needlenose pliers, or pull apart the pump and ream the impeller vanes with a length of wire or a small screwdriver. Fitness View More. https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS the sound may possibly be a problem with the internal bypass, located in the front header. Could have been an outlet problem too, make sure wires or terminals arent touching anything except each other. Hi Larry, When DE is coming back into the pool, its usually: Normally when the device is turned off and we do get the lid off, water runs back into the basket from the filter, it almost sounds like its creating almost a vapor lock, like in an engine. Or maybe a clamp? Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? Have an old Hayward super II pump, worked fine last fall, this spring at startup very low volume. I just went out there to crank them up, after 10 minutes they shut off. Hi, the yellow wire could have been hit by the whirling centrifugal switch in the center rear of the motor, or could have burned thru from touching something very hot. If you can grab the bolt head underneath the pad with pliers, that could help, otherwise you can cut the bolts off using a reciprocating saw with a metal blade. Some pumps are a bit difficult to remove, even when you have removed the right bolts/clamp sometimes they need to be pried apart with a screwdriver, to separate the pump. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
Manually spinning the shaft can break the rust bonds. We would like to show you a description here but the site wont allow us. Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. There are two washers that I have on each side of the spring. The Pool is a Roman 23 in ground. My 2 year old 1.5 HP above ground Hayward pool pump worked fine last year. IF the shaft does spin freely, yet the breaker trips, check the wiring for wires touching each other or the motor housing, loose wires, broken wires or corroded wires or water in the conduit, surrounding broken wires. Thanks. I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. What should I do? Lube should not be the issue with the leak, not required. I have an Ecostar That has developed a pinhole spray leak at the top of where the pump housing oring sits between the pump and motor. Motors have a thermal overload switch (in the rear of the motor, top-dead-center, at 12:00). Touch both leads of your meter to the capacitor terminals, does not matter which lead touches which terminal. have an old hayward flo lx pump and sounds like it is turning on with a click but wont start sucking the water from the pool through the pump to the filter. Step 2: Did you properly install your switch? If the motor label says 115V/230V it is reversible, but if it says just 230V, Hi Chad, Just installed a replacement Super Pump and realized a point that may help others as they install. If none found, inspect your valve settings, on the equipment pad, and make sure everything is normal, and the cleaner water flow is not being throttled or bypassed. Did I mention low water level, stuck skimmer weirs, or clogged skimmer baskets? Question, if I can determine which return pipe is broke could I just block off that return and bypass it. If the shaft is free turning, but the pump does not turn on, check power connections. Holy smokes! Inspect the circuit board, blow off with some air, and look closely at the 3 wires for any insects, spiderwebs or corrosion of any type. You could also adjust the pressure switch (on most heaters), to allow it to come on with slightly less pressure, (1 psi instead of 2 psi). Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Can I replace a specific part or do I have to buy a new one? Hi Davy, better tool to use? Look closely at the centrifugal switch in the middle/center/end of shaft, make sure its tight and intact. I have a Heyward VS 500 that suddenly started making a sound like a poker card stuck in your spokes of your bike at all speeds. I have an above ground 18,000gal poola Hayward SP1580X15 Power-Flo LX 1 1/2 HP pump purchased May 2017. I next realized the shaft (impellers) was frozen, and was able to free it up so it now spins smoothly. It spins easily by hand and doesnt make any noise. Plaster and vinyl surfaces in particular, can become damaged when exposed to hot summer weather, and stained, if that applies or matters in your case. Home; Events. That motor is sometimes used on the Hayward Superpump which is the only pump with a SQUARE pump basket. Hi Davy~ Inspect the motor shaft for any obstructions. Hope that helps! I replaced the start capacitor as that sounded like that was the most likely culprit based on everything I read, but noise still persisted. There was alot of debris once I removed the assemblies and some water below wiring. You can check power in, on the incoming wires, and power out (with timer ON), on the outgoing wires that go to the motor. When I then switch the pump breaker off and then back on again it springs into life (every time). Pool Supplies Near Me Open Now, I also suspect a bad pressure gauge, if flow is nearly non-existant, pressure should be very low. It sounds more like a filter problem, one that might be fixed by using a good pool filter cleaner, or you may need new filter media. Higher horsepower motors are usually only 230V, above 2 hp, but lower hp motors are sometimes reversible, or have the ability to wire either with 110V or 220V, but they will say this on the motor label if they are (reversible) and have a diagram also. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. There can be multiple reasons for a pool pump not priming correctly. If there is air in the basket it hums away loudly and sucks great to prime and fill the basket (the saltwater thing even appears to be working). I even plugged in the old pump and that too did not run? Took it to pool mart and they cleaned it out and said everything was fine inside it. Checked everything still doesnt work . Thank you so much for taking time to answer all our concerns. , I have a 1 hp Hayward 2 speed motor. I checked the possible issues that you mentioned hereno drain plugs on the systemdraining pool is done through the filter via a valve that is after the filter (Perflex). By looking at the return valve, you should be able to see if it is squarely closing off the pool return pipes. Checked pump, and appeared that pump had to keep priming . Came out tonight and flipped the switch and pump started. Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. My pump & filter are Haywards. There should be no continuity. Hope thats not the case. my hayward pump will only work when the nob is turned to 110 I just got my home back, I walked outside and pool level was well below jets. Check the tightness on all wire connections, on the breaker, timeclock and motor. You can experiment with pump RPM settings, to exceed the threshold. The pump never turns off but it should pull the water through constantly. I need some advice for my 15 x 30 x 48 AG oblong swimming pool. Hi Sean, the Powerflo pump lid has a very tight seal, likely the o-ring needs to be removed, cleaned off with a rag, replaced and lubed with a Teflon lubricant like Magic lube or other Pool Lube. Had the filter for 3 years. Still the same results. from If you have trouble getting past this, an electrician may be a good call to make. Unusual, but it could be the only problem, I would replace the capacitor with the same size (match the MFD number), and check that the shaft rotates freely when mounted to the pump. I was hoping that you can give me some advice. A very thin layer of rust develops between the stator and the rotor inside the motor, and getting a 7/16 open end wrench on the end of the shaft, and working it back and forth, breaks the rust and frees up the shaft to spin. Check if the pump will now run. Nothing tripped. i have a 4 wire set up, ground, line , low speed,high , just want to make sure i wire correctly, 1- line 1, 2- high speed, 3or4 to low speed? Any thoughts? Blower vacuum switch closed when expected open error, If the blower prover switch is closed before blower start-up the control will not start the blower. Any ideas as to how to fix this? IF thats good, check the pipe coming into the pump, does it drip when the pump is off? I primed the pump and was ready to add DE compund. If I let it sit I can turn it on again, but just for about 20 seconds. I have a Hayward H250 pool heater with a digital display. Hi Renaud, many motors come wired to accept 230V, but are reversible to 115V. Hi Kelly, the first thing that comes to mind when you say pump stuck, is the common occurrence of rust building up between the rotor and stator, inside the motor. Another oddity is both failure are upon Spring re-opening,and the pumps ran flawlessly throughout each summer? Hello, my motor runs for 20 seconds then stops. Just opening pool. Also check that no wires are touching any metal, and check for any bare/scraped wires. Had a ball stuck under the skimmer basket, pump got hot and now will not turn back on. My pool pump was running fine until I turned it off. Hi Jim, make sure the shaft of the motor (and the impeller) is spinning freely, rust can build up internally, and create a frozen pump in spring. All Rights Reserved. I was just wondering if you thought that could be the issue unless it could be something else. I am very sure the water comes from underneath, not from plumbing fitting threads. ), hard to tell until the pump can be tested. The impeller does not need to be spun on too tight, the spin direction of the shaft will keep it snug, so just hand tight. Pump is less than 3 years old. If you have an automatic controller, it could be a rickety relay or something.

Jesse Jones, Kiro 7 Cancer, Articles H